XP13000EH - Great Generator At A Great Price
Edit 6/19/25 Strong storm cell came through our area; high winds and driving rain. Moved in and out quickly so everything seemed normal. A few hours later, power went out. Power was out 9 hours. The 1300EH fired right up and ran 8 hours on a full tank of fuel (gas). That seems to be the average time (in hours) with a nominal load. Edit 6/18/25 Still running great. I usually start it by hand just to see if it starts easily and it does. 80 hours on it so far. Have not tried the propane option yet, but have tanks available if needed. I try and run the generator at least every few months (for 15 minutes or so) to ensure the fuel lines stay clear and dust off the cobwebs. Each time I add fuel, I use Stabil fuel stabilizer since its hard to tell how long it might be before the generator is used again. I also add B12 Chemtool to at least one tank of fuel a year. Follow recommendations on B12 can for ratio. The B12 also helps keep varnish and junk from clogging up the carburetor. These two fuel additives work magic when used in small equipment engines that are not run often. You will never have a start-up issue when using these additives. Edit 9/30/24 Generator is running great still. Lost power at 5:40AM due to remnants of Hurricane Helene. Power companies are trying to restore power and probably had to shut off adjacent grids to make the repairs. Edit 7/23/22 We recently upgraded to a 3 ton compressor & evap coil (same air handler) due to the previous 2 ton compressor dying a slow death. The 3 ton compressor uses about 1000 watts more than the 2 ton compressor. The XP13000EH can easily handle the extra load. To help with turn-on surge, I turn the air handler fan from AUTO to ON, this way the air handler is already running and when the thermostat calls for AC, only the compressor will need the surge current to get up and running in that split second. With both HVAC units running the load is about 6000 watts, so I have approximately 4500 watts to run the rest of the house, which is more than sufficient to be comfortable when the power is out. As far as sensitive electronics, the only issue I have had is with a UPS (back-up power supply), but other than that, the 13000EH runs everything just fine, no issues. Desktop & laptops use a switching power supply, so those kinds of supplies don't need a perfect sine wave to operate. My old school air handler (regular squirrel cage motor) runs fine of the 13000EH too. End of edits. Original Review: We bought this generator based on other reviews and it has been dependable and powerful. One item that I wish they would address possibly in future models or a change is the muffler; it is a bit loud, but other than that, the generator is awesome. We live in north central North Carolina where power is fairly reliable, but has gone out periodically more than I thought it would and purchased the 13000EH as a whole house generator. The 13000EH is connected thru a 60 amp transfer switch and runs the following with ease: Two 2-ton HVAC heat pump units with gas furnace assist 1000 watt microwave oven Standard size fridge Two chest freezers Home office and networking equipment (computers, printer, etc) TV, Dish receiver, audio equipment Various LED lighting and ceiling fans Two bedrooms (lights and receptacles) Although some reviews have stated that the THD of this generator (this series in general) is higher than some other more expensive brands, we have not had any issues with our computers or other electronics being run off of the 13000EH. The generator has about 50 hours on it. It easily pull starts even though it has an electric starter too. Very happy with it’s performance so far. I have only run it on gasoline so far, not propane, but do have propane tanks as a secondary fuel source. Read more